激情综合色综合啪啪开心,亚洲国产AV美女网站,亚洲国产一二三精品无码蜜臀,国产成人精品国内自产拍免费看

Proton Therapy Systems
High AccuracyHigh Cure RateFast TreatmentFewer Side-effects
Effective for malignant tumours of the brain, spinal cord tumours, cerebrovascular diseases, head and neck tumours, eye lesions, thoracic and abdominal tumours, paediatric tumours and other diseases.
Parameters
Treatment RoomFixed-beam Treatment Room/ Gantry Room
Dose Rate≥2 Gy/(L.min)
Beam Intensity>800 nA
ParticleProton
Treatment HeadPencil Beam Scanning
Continuously Adjustable Energy Range70-220 MeV
Maximum Energy240 MeV
Radiation Field30 cm×40 cm
Introduction
  • Superconducting Cyclotron
    Superconducting technology.
    Continuous high-dose intensity modulated.
    High efficiency.
  • 360° Gantry Room
    Lightweight.
    Full 360° treatment angle.
  • Cone-beam CT image Guidance System
    Performing a 360° scan around the patient to acquire the precise position of tumor area, minimizing radiation exposure to normal tissues.
  • Fixed-beam Treatment Room
    Large fixed irradiation field, cost-effective.
    Primarily used for the treatment of head and neck tumors, particularly suitable for lesions such as skull base chordomas and malignan.
Advantages
  • Flexible Configuration
    Personalized solutions are available, with single- or multi-room proton therapy systems tailored to clinical and research needs.
  • High Efficiency
    Scientific system operation process, fully optimised working logic, the average treatment time of 15 minutes per session; Flash technology allows brief but high dose tumor radiation, effectively reducing treatment duration.
  • Compact Structure
    Superconducting technology enables small size, light weight, low energy consumption, thereby reducing floor space and construction costs.
  • Customized Interface
    Customized development to clinical needs, lightweight interface library, bilingual (English and Chinese) user interface for ease of operation.
  • Patient-centered Care
    The gantry room reflects the concept of "Reinvent Yourself as a Butterfly", effectively relieving patients' psychological discomfort during the treatment process and ensuring the therapeutic effect.
  • High Accuracy
    Advanced pencil beam scanning technology ensures continuous and stable beam current, rapid intensity modulation; fully rotating gantry and precise image guidance system enable flexible irradiation
Options
  • CAPRO-S(1 room)
    The footprint of the single-room proton therapy system is approximately 400 m2
  • CAPRO-C (2 rooms)
    The footprint of the 2-rooms proton therapy system is approximately 600 m2.
    CAPRO-C (1 gantry room, 1 fixed treatment room)
  • CAPRO-X (multi-rooms)
    Multi-room system can be configured with treatment rooms according to demand, causing higher cost and larger footprint.
    CAPRO-X(2 gantry rooms, 1 fixed treatment room)
    CAPRO-X(3 gantry rooms)
Parameters Introduction Advantages Options
肥东县| 中西区| 巴彦淖尔市| 朝阳市| 六盘水市| 新昌县| 兴海县| 静安区| 嵊泗县| 桦南县| 出国| 葵青区| 瓮安县| 平山县| 饶阳县| 大荔县| 汉川市| 九龙县| 博白县| 胶南市| 克山县| 新闻| 德钦县| 蕲春县| 汪清县| 高台县| 淮南市| 乳源| 建始县| 峨山| 郓城县| 格尔木市| 泰安市| 玛多县| 平陆县| 谷城县| 惠水县| 于田县| 定结县| 巫山县| 宁德市|